Power & Diagnostics

Laptop No Power Repair: Tracing the 19V Rail, Input MOSFETs, and Current-Sense Resistors (CLR)

Step-by-step bench methodology for diagnosing completely dead laptops: testing the DC jack, first and second N-channel/P-channel input MOSFETs, charger IC ACDET/ACOK, and B+ rail shorts.

By admin·
Laptop No Power Repair: Tracing the 19V Rail, Input MOSFETs, and Current-Sense Resistors (CLR)

When a laptop arrives on the bench completely dead—no charging LED, zero current draw, or immediate bench power supply over-current trip—the very first circuit to test is the 19V primary input stage (B+ / VIN / DCBATOUT). Nearly 40% of all no-power motherboard faults live right here.

1. Anatomy of the 19V Input Protection Stage

Unlike a simple wire from the DC jack to the board, modern laptops place two back-to-back MOSFETs (commonly labeled PQ1 and PQ2, or Q1/Q2) in series, followed by a low-value Current-Limit / Current-Sense Resistor (CLR, typically 0.010 Ω / R010 or 0.020 Ω / R020):

  • First MOSFET (Reverse-Polarity & Input Isolation): Blocks reverse current from the battery from back-feeding into the DC jack.
  • Second MOSFET (Over-Current & Short Protection): Controlled by the charging IC (such as TI BQ24780S, BQ24725A, or Renesas ISL88739). If the charger IC senses a short or abnormal adapter voltage, it drops gate drive (ACDRV) to 0V, disconnecting the rest of the motherboard from 19V.
  • Current-Sense Resistor (CLR): Allows the charger IC (via ACP and ACN pins) to measure total adapter current draw in real time.

2. Step-by-Step Resistance & Voltage Testing

Always start in resistance/diode mode with power disconnected!

  1. Measure resistance to ground on the CLR (B+ rail): Place black probe on a clean ground pad and red probe on the CLR. A healthy B+ rail typically reads several kilo-ohms to mega-ohms (or > 0.400V in reverse diode mode). If you read 0–5 Ω, you have a dead short on the main 19V rail—do not blindly plug in a standard 90W charger.
  2. Check MOSFET Gate-to-Source and Drain-to-Source shorts: Measure across Source–Drain and Gate–Source on both PQ1 and PQ2. A shorted input MOSFET often blows because of a cheap non-OEM charger spike.
  3. Apply 19V via a current-limited bench PSU (set to 19V, 1A limit):
    • Check DC-IN before PQ1: must be 19.0V.
    • Check between PQ1 and PQ2: if 19V stops here, check PQ1 gate voltage. For N-channel MOSFETs, gate drive (ACDRV) must be ~24V–25V (about 5–6V above the 19V source via the charger IC's internal charge pump). For P-channel MOSFETs, gate voltage must be pulled lower than 19V (typically ~8–10V).
    • Check after PQ2 (on the CLR): must be 19.0V.

3. Why ACDRV Stays at 0V (Charger IC Conditions)

If PQ1 and PQ2 are healthy and there is no short on B+, yet ACDRV remains 0V, verify the four mandatory input conditions on the charger IC (e.g., BQ24780S):

Pin NameHealthy ValueWhat It Means If Wrong
VCC~19V (via protection diode)Open series resistor (typically 10 Ω) or shorted VCC filter capacitor.
ACDET2.4V – 2.8VResistor voltage divider from 19V is corroded or open; IC thinks adapter is absent.
REGN~6.0V LDO outputInternal LDO dead or shorted bootstrap cap — charger IC itself must be replaced.
ACOK3.3V (open-drain pulled up)Signals the EC that valid AC power is present.

4. Isolating a B+ Short Circuit Safely

If the CLR measures near 0 Ω to ground, the short could be a cracked ceramic decoupling capacitor (MLCC) on B+, or—far more dangerously—a shorted high-side CPU VCORE MOSFET connecting the 19V rail directly to the 1V CPU core! Never inject 19V into a shorted B+ rail: always check resistance between the CLR and every secondary buck inductor (VCORE, VCCGT, RAM, 3V/5V). If a VCORE coil also reads ~0 Ω to the CLR, remove that high-side MOSFET before injecting any low voltage (1V, 1–2A) to find hot components.